1. Home
  2. Products
  3. 100 kW 1500 V DC/DC Isolated Power Converter

Overview

The new ADVANTICS ADB Series is a system of stackable power modules for DC Fast Charge stations supporting CCS, NACS, and MCS charging standards, as well as various energy storage system applications and industrial power systems. Its no-compromises design is fully sealed and liquid cooled to ensure the highest levels of reliability in any operating environment. From corrosive coastal regions, to the humid tropics, to scorching hot deserts, to the frigid arctic, it can handle them all.

The ADM-PC-DC01 is the first product on the market specifically designed to be MCS (Megawatt Charging System) compliant. Supporting the full 200 - 1500 V output voltage range (R-MCS), and paralleling up to 6 MW.

The integrated gateway allows for easy firmware update, isolated CAN bus interface, parallel stack management and cybersecurity.

As a vertically integrated company, we don’t rely on 3rd party black boxes and are therefore able to give our customers full control of their system.

All of ADVANTICS products are proudly designed and manufactured in the European Union.

Characteristics

  • Bidirectional DC/DC power module

  • SiC technology

  • Reinforced isolation

  • 98 % peak efficiency, wide power range

  • Wide output range, 200 - 1500 V, ±220 A

  • Watercooling, no air circulation needed

  • IP67 sealed design

  • CAN bus control, HW interlock

  • Can be easily paralleled to MW levels

  • Integrated input fusing

Applications

  • Electric Vehicle DC chargers

  • CCS1, CCS2, NACS, MCS, CHAdeMO

  • Energy Storage Systems

  • V2G (Vehicle 2 Grid) systems

  • AC and DC microgrids

  • Onboard charging for off-highway and heavy duty machinery

  • EV and charge simulators

  • Laboratory bi-directional power suppliers

  • Harsh environments (marine, coastal areas, mining)

Technical Data

DC bus side (A)

Voltage range

750 - 950 V

Current

±120 A

Max power

100 kW

Current measurement accuracy

±1 % of full-scale

Voltage measurement accuracy

±1 % of full-scale

Wiring

DC+, DC-

DC link capacitance

160 uF

DC link precharge

No, must be precharged externally

DC bus to PE separation

Reinforced isolation

Protection

Overvoltage, undervoltage, overcurrent, overtemperature

Fusing

On the positive line UL/IEC rated

Connectors

2x RADSOK Size 8 mm Amphenol SurLock Plus (SLP-HIR-B)

DC output side (B)

Voltage range

200 - 1500 V

Current

±220 A (bidirectional), limited by power envelope

Max power

100 kW

Current measurement accuracy

±1 % of full-scale

Voltage measurement accuracy

±1 % of full-scale

Wiring

DC+, DC-

DC link capacitance

25.7 uF (QP), 6.4 uF (QS)

Primary-secondary separation

Reinforced isolation

Ripple voltage/current

Fulfills IEC 61851-23-3

Output contactors

No

Protection

Overvoltage Undervoltage Overcurrent Overtemperature

Connectors DC

2x RADSOK Size 10.3 mm, Amphenol SurLock Plus (SLP-HIR-C)

Low voltage and communication

Communication interface

CAN 2.0B

External control power supply voltage

24 nominal (20-28) V

Control power consumption

85 W

Standby power consumption

5 W

Isolation concept

CAN and 24 V isolated from PE CAN bus isolated from 24 V Basic isolation, reinforced towards HV

Connectors

2x for CAN, 1x for power

Paralleling of converters

Up to 120 units in parallel

Mechanical

Dimensions

700 x 400 x 165 mm

Weight

47 kg

Cooling

50/50 Water Ethylene Glycol Mix

Noise

No fan noise, watercooled

Mounting

4U rack, or custom brackets

Environment

Operating temperature range

-40 to 70 °C, derating applies

Ingress protection code

IP67

Allowed pollution degree

3 external environment

Altitude

3000 m

Shock

Pending

Vibrations

Designed for harsh environments

Standards and Isolation

Designed to following standards

IEC 61851-1, IEC 61851-23 ED2, IEC 62477-1, UL2202, UL1741

Grid code support

EN50549-1, IEEE 1547, VDE-AR-N 4100, UK G99, AS 4777.2

Electromagnetics compatibility

EMC class B with an external filter

Overvoltage category

OVC-II up to 3000 m

Impulse withstand voltage

4 kV for all barriers

Clearance distance

Min. 3.42 mm for all barriers

Creepage distance

Min. 5.2 mm (in PD1 microenvironment) Min 8.5 mm otherwise for all barriers

Port A to Case

Reinforced isolation 4 kV impulse

Port B to Case

Reinforced isolation 4 kV impulse

Port A to Port B

Reinforced isolation 4 kV impulse

Port A to Control

Double isolation 4 kV impulse

Port B to Control

Double isolation 4 kV impulse

Control to Case

Functional isolation 3 kV HiPot

Design and Manufacturing

EU

Please note that the technical data presented on the website is for reference only and may be subject to change without prior notice.

Take a closer look

Example applications